Calibration Error Troubleshooting

Calibration Error Troubleshooting

Common causes:

  • Clogged filter or nozzle blocking flow (often from unflushed FlexPipe/Swing Joint)

  • Pressure too high or too low

  • Flow meter misconfigured or failing

  • Another active error interfering with calibration

  • Head requires manual calibration (no pressure sensor)

What to do:

  • Check that pressure is constant between 40–80 PSI

  • Remove the nozzle and clean the filter

  • Reinstall and run calibration again

If you have a flow meter, try turning it off, then back on after calibration.

If calibration still fails, check for other errors on the Zone screen or switch to manual calibration if needed.