Skip to Content
Try this solution

FlexPipes, Swing Joints, and Sprinkler 3

You can use your existing FlexPipe with Sprinkler 3. We recommend our new swing joint, but a simple adapter works too!

Using a homemade adapter with FlexPipe:

  1. Add Teflon tape to the FlexPipe ¾" fitting

  2. Add Teflon tape to the 1" male end of Sprinkler 3

  3. Connect the threaded fitting to the FlexPipe and Sprinkler 3 and tighten with a wrench

Using FlexPipe with the swing joint:

  1. Add a PVC 1" to ¾" threaded union

  2. Add Teflon tape to the swing joint and FlexPipe threads on both sides of the union

  3. Connect the FlexPipe and swing joint to the union and tighten with a wrench

  4. Connect the swing joint to Sprinkler 3 (no Teflon tape or tools needed)

You can also replace the FlexPipe entirely with the swing joint attachment.