Calibration Error

Calibration is failing.

Top Causes

● Debris is in the filter under nozzle obstructing water flow. FlexPipe was not flushed properly before installing head.
● Water pressure (PSI) at the head is too high and needs pressure regulation; could also be low and unable to run an Irrigreen system.
● Flow meter (if installed) is either incorrectly configured in System Setup or failing (see flow error for more info on flow meters).
● Calibration fails due to another error that interferes with it.
● Head may not have a pressure sensor and needs manual calibration (enabled in System Setup)

Measure your pressure and ensure you have CONSTANT pressure between 40-80 PSI, unscrew the nozzle and remove the filter below and clean any debris out of filter. Re-calibrate.